海洋盐度卫星L波段一维综合孔径辐射计数字子系统关键性能测试方法

    Key Performance Test Methods for Digital Subsystem of L-band One-dimensional Synthetic Aperture Radiometer for Ocean Salinity Satellite

    • 针对中国首颗海洋盐度卫星主被动探测仪(MICAP) L波段一维综合孔径辐射计分布式数字子系统的高精度测试需求, 聚焦分布式架构下多节点同步、软硬件耦合误差分离等难题. 测试过程中, 利用多机同步触发和FPGA的ILA (Integrated Logic Analyzer)工具, 实现24路AD原始数据对齐, 解决了分布式架构下原始数据无汇聚点的难题; 同时提出硬件性能与整体性能双向印证的测试方法, 完成了软硬件解耦效果的评估. 实测结果显示, 幅度一致性≤0.4 dB, 相位一致性≤1°, 相关偏置≤–38 dB, 各项指标均符合任务要求. 研究成果已应用于MICAP工程研制, 为星载分布式数字子系统的性能验证与优化提供了关键技术支撑.

       

      Abstract: The Microwave Imager Combined Active and Passive (MICAP), the first ocean salinity detection satellite in China, realizes the global scale measurement of key geophysical elements such as ocean salinity and soil moisture through multi-factor fusion inversion. The high-sensitivity L-band one-dimensional Synthetic Aperture Radiometer (SAR), serving as the primary detector for MICAP, features a digitally implemented subsystem with a distributed architecture that constitutes the core module of the radiometer’s receiving chain. The subsystem’s key performance indicators directly affect the measurement accuracy of both the radiometer and MICAP in detecting ocean salinity, thus the mission imposes stringent performance requirements. This study addresses the high-precision performance testing needs of the distributed digital subsystem, focusing on challenges such as synchronized multi-node data acquisition under a distributed framework and separation of hardware-software coupling performance. The testing method employs multi-device synchronous triggering and the Integrated Logic Analyzer (ILA) tool embedded in the FPGA of front-end data acquisition units to achieve synchronous capture of original AD sampling data from 24 channels across multiple individual units. This solution resolves the absence of original data aggregation points among multiple front-end data acquisition units in the distributed architecture. Furthermore, the study proposes a bidirectional verification framework for both hardware and system-level performance. The hardware performance is tested by analyzing raw acquired data, while the integrated hardware-software performance is evaluated by processing the end-to-end scientific data packets. This methodology achieves decoupled testing of the hardware and software performance of the distributed digital subsystem. The actual test results, including amplitude consistency ≤0.4 dB, phase consistency ≤1º, and correlation bias ≤–38 dB, meet the mission's specified requirements. The research results have been applied to the MICAP engineering development, providing critical technical support for the performance verification and optimization of the distributed digital subsystem of ocean salinity satellite synthetic aperture radiometer.

       

    /

    返回文章
    返回